Why does a HAVE QUICK II network need a time reference?
In frequency-hopping mode, each radio computes which channel to hop to from the time of day (TOD) and the network key (WOD). If the radios do not share the same precise time, they hop to different channels and stop hearing each other. A common reference such as RZT289 gives every radio the same GNSS-derived time.
What is HAVE QUICK TOD?
It is the Time of Day code that HAVE QUICK and SATURN radios receive through their synchronization interface. Per ICD-GPS-060, one frame per second carries hour, minute, second, day of year, year and the TFOM quality indicator, together with a 1PPS pulse marking the exact start of each second.
What is TFOM?
The Time Figure of Merit states the estimated error of the delivered time relative to UTC, on a scale from 1 to 9. RZT289 declares TFOM 4 (100 ns to 1 µs) while receiving GNSS and degrades it progressively and honestly if the signal is lost, so the radio knows how far it can trust its synchronization.
What happens if the GPS signal is lost?
The unit enters holdover: it keeps delivering TOD and 1PPS from its internal oscillator, which has learned and compensates for its own drift. RZT289-S holds TFOM 6 for 1.5 minutes; RZT289-OX, with OCXO, holds TFOM 4 for 1 hour and TFOM 6 for 24 hours.
Is it compatible with SATURN radios?
Yes. SATURN (STANAG 4372) is the evolution of HAVE QUICK II (STANAG 4246) and uses the same TOD and 1PPS synchronization interface, so RZT289 serves both networks.
Which GNSS receiver does it use?
It receives GPS L1 C/A and BeiDou B1I simultaneously, with an active antenna powered by the unit through a female SMA connector, and detects an open or short-circuited antenna.